#!/bin/bash
RETRIES="{{ handler_health_rgw_check_retries }}"
DELAY="{{ handler_health_rgw_check_delay }}"
HOST_NAME="{{ ansible_hostname }}"
RGW_NUMS={{ radosgw_num_instances }}
RGW_BASE_PORT={{ radosgw_frontend_port }}
RGW_FRONTEND_SSL_CERT={{ radosgw_frontend_ssl_certificate }}
if [ -n "$RGW_FRONTEND_SSL_CERT" ]; then
RGW_PROTOCOL=https
else
RGW_PROTOCOL=http
fi
declare -a DOCKER_EXECS
for ((i=0; i<${RGW_NUMS}; i++)); do
DOCKER_EXECS[i]=""
2019-05-08 04:33:21 +08:00
{% if containerized_deployment | bool %}
CONTAINER_NAME="ceph-rgw-${HOST_NAME}-rgw${i}"
DOCKER_EXECS[i]="{{ container_binary }} exec ${CONTAINER_NAME}"
{% endif %}
done
RGW_IP={{ hostvars[inventory_hostname]['_radosgw_address'] }}
SOCKET_PREFIX="/var/run/ceph/{{ cluster }}-client.rgw.${HOST_NAME}.rgw"
check_socket() {
local i=$1
local succ=0
local count=10
# Wait and ensure the socket exists after restarting the daemon
while [ $count -ne 0 ]; do
SOCKET=$(grep ${SOCKET_PREFIX}${i} /proc/net/unix | awk '{ print $8 }')
if [ -n "${SOCKET}" ]; then
${DOCKER_EXECS[i]} test -S ${SOCKET} && succ=$((succ+1)) && break
fi
sleep $DELAY
let count=count-1
done
if [ $succ -ne 1 ]; then
echo "Socket file ${SOCKET} could not be found, which means Rados Gateway is not running. Showing ceph-rgw unit logs now:"
journalctl -u ceph-radosgw@rgw.${HOST_NAME}.rgw${i}
exit 1
fi
}
check_for_curl_or_wget() {
local i=$1
if ${DOCKER_EXECS[i]} command -v wget &>/dev/null; then
rgw_test_command="wget --no-check-certificate --tries 1 --quiet -O /dev/null"
elif ${DOCKER_EXECS[i]} command -v curl &>/dev/null; then
rgw_test_command="curl -k --fail --silent --output /dev/null"
else
echo "It seems that neither curl nor wget are available on your system."
echo "Cannot test rgw connection."
exit 0
fi
}
check_rest() {
local i=$1
check_for_curl_or_wget ${i}
local succ=0
while [ $RETRIES -ne 0 ]; do
2019-05-08 04:33:21 +08:00
${DOCKER_EXECS[i]} $rgw_test_command $RGW_PROTOCOL://$RGW_IP:$((RGW_BASE_PORT+i)) && succ=$((succ+1)) && break
sleep $DELAY
let RETRIES=RETRIES-1
done
if [ $succ -ne 1 ]; then
# If we reach this point, it means there is a problem with the connection to rgw
2019-05-08 04:33:21 +08:00
echo "Error connecting locally to Rados Gateway service: $RGW_PROTOCOL://$RGW_IP:$((RGW_BASE_PORT+i))"
exit 1
fi
}
for ((i=0; i<${RGW_NUMS}; i++)); do
2019-05-08 04:33:21 +08:00
# First, restart the daemon
systemctl restart ceph-radosgw@rgw.${HOST_NAME}.rgw${i}
2019-05-08 04:33:21 +08:00
# Check socket files
check_socket ${i}
2019-05-08 04:33:21 +08:00
# Check rest
check_rest ${i}
done