mirror of https://github.com/ceph/ceph-ansible.git
ceph-osd: Increase cpu limit to 4
In containerized deployment the default osd cpu quota is too low
for production environment using NVMe devices.
This is causing performance degradation compared to bare-metal.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1695880
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit c17106874c
)
pull/3917/merge
parent
92340d049c
commit
d8688e0eb9
|
@ -122,7 +122,7 @@ dummy:
|
|||
# Default values are based from: https://access.redhat.com/documentation/en-us/red_hat_ceph_storage/2/html/red_hat_ceph_storage_hardware_guide/minimum_recommendations
|
||||
# These options can be passed using the 'ceph_osd_docker_extra_env' variable.
|
||||
#ceph_osd_docker_memory_limit: "{{ ansible_memtotal_mb }}m"
|
||||
#ceph_osd_docker_cpu_limit: 1
|
||||
#ceph_osd_docker_cpu_limit: 4
|
||||
|
||||
# The next two variables are undefined, and thus, unused by default.
|
||||
# If `lscpu | grep NUMA` returned the following:
|
||||
|
|
|
@ -114,7 +114,7 @@ ceph_config_keys: [] # DON'T TOUCH ME
|
|||
# Default values are based from: https://access.redhat.com/documentation/en-us/red_hat_ceph_storage/2/html/red_hat_ceph_storage_hardware_guide/minimum_recommendations
|
||||
# These options can be passed using the 'ceph_osd_docker_extra_env' variable.
|
||||
ceph_osd_docker_memory_limit: "{{ ansible_memtotal_mb }}m"
|
||||
ceph_osd_docker_cpu_limit: 1
|
||||
ceph_osd_docker_cpu_limit: 4
|
||||
|
||||
# The next two variables are undefined, and thus, unused by default.
|
||||
# If `lscpu | grep NUMA` returned the following:
|
||||
|
|
|
@ -5,6 +5,7 @@
|
|||
########
|
||||
# MAIN #
|
||||
########
|
||||
{% set cpu_limit = ansible_processor_vcpus|int if ceph_osd_docker_cpu_limit|int > ansible_processor_vcpus|int else ceph_osd_docker_cpu_limit|int %}
|
||||
|
||||
{% if ceph_osd_numactl_opts != "" %}
|
||||
numactl \
|
||||
|
@ -20,9 +21,9 @@ numactl \
|
|||
--memory={{ ceph_osd_docker_memory_limit }} \
|
||||
{% endif -%}
|
||||
{% if (container_binary == 'docker' and ceph_docker_version.split('.')[0] is version_compare('13', '>=')) or container_binary == 'podman' -%}
|
||||
--cpus={{ ceph_osd_docker_cpu_limit }} \
|
||||
--cpus={{ cpu_limit }} \
|
||||
{% else -%}
|
||||
--cpu-quota={{ ceph_osd_docker_cpu_limit * 100000 }} \
|
||||
--cpu-quota={{ cpu_limit * 100000 }} \
|
||||
{% endif -%}
|
||||
{% if ceph_osd_docker_cpuset_cpus is defined -%}
|
||||
--cpuset-cpus='{{ ceph_osd_docker_cpuset_cpus }}' \
|
||||
|
|
Loading…
Reference in New Issue