With OpenSSL version prior 1.1.1 (like CentOS 7 with 1.0.2k), the -addext
doesn't exist.
As a solution, this uses the default openssl.cnf configuration file as a
template and add the subjectAltName in the v3_ca section. This temp openssl
configuration file is removed after the TLS certificate creation.
This patch also move the run_once statement at the block level.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1978869
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 5e0ace7e54)
the current way the variable is built results in:
```
2021-08-03 04:18:23,020 - ceph.ceph - INFO - ok: [ceph-sangadi-4x-indpt6-node1-installer] => changed=false
ansible_facts:
subj_alt_names: |-
subjectAltName=ceph-sangadi-4x-indpt6-node1-installer/subjectAltName=10.0.210.223/subjectAltName=ceph-sangadi-4x-indpt6-node1-installersubjectAltName=ceph-sangadi-4x-indpt6-node2/subjectAltName=10.0.210.252/subjectAltName=ceph-sangadi-4x-indpt6-node2/
```
which is incorrect.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1978869
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 6f1a0634f7)
sufficient for the default value (512) of rgw thread pool size.
But if its value is increased near to the pids-limit value,
it does not leave place for the other processes to spawn and run within
the container and the container crashes.
pids-limit set to unlimited regardless of the container engine.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1987041
Signed-off-by: Teoman ONAY <tonay@redhat.com>
(cherry picked from commit 9b5d97adb9)
The balancer status is registered during the cephadm-adopt, rolling_update
and swith2container playbooks. But it is also used in the ceph-handler role
which is included in those playbooks too.
Even if the ceph-handler tasks are skipped for rolling_update and
switch2container, the balancer_status variable is erased with the skip task
result.
play1:
register: balancer_status
play2:
register: balancer_status <-- skipped
play3:
when: (balancer_status.stdout | from_json)['active'] | bool
This leads to issue like:
The conditional check '(balancer_status.stdout | from_json)['active'] | bool'
failed. The error was: Unexpected templating type error occurred on
({% if (balancer_status.stdout | from_json)['active'] | bool %} True
{% else %} False {% endif %}): expected string or buffer.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1982054
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 386661699b)
The ceph osd pool ls detail command is a subset of the ceph osd dump
command.
$ ceph osd dump --format json|wc -c
10117
$ ceph osd pool ls detail --format json|wc -c
4740
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 06471a4b82)
When the ceph dashboard user creation fails then the issue is hidden
as we don't check the return code and don't print the error message
in the module output.
This ends up with a failure on the ceph dashboard set roles command saying
that the user doesn't exist.
By failing on the user creation, we will have an explicit explaination of
the issue (like weak password).
Closes: #6197
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 17784624e0)
eec3878 introduced a regression for upgrade scenarios where there's no
monitor nodes at all (like ganesha standalone, external clients, etc..)
TASK [get the ceph release being deployed] ************************************
task path: infrastructure-playbooks/rolling_update.yml:121
Thursday 29 July 2021 15:55:29 +0000 (0:00:00.484) 0:00:15.802 *********
fatal: [client0]: FAILED! =>
msg: '''dict object'' has no attribute ''mons'''
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit e87a47cf0c)
In the `set osd flags` block, run the Ceph commands that gather information
from the cluster (and don't make any changes to it) even when running in check
mode.
This allows the tasks that depend on the variables set by those tasks to
succeed in check mode.
Signed-off-by: Benoît Knecht <bknecht@protonmail.ch>
(cherry picked from commit d7653dca95)
Run the Ceph commands that only gather information (without making any changes
to the cluster) when running Ansible in check mode.
This allows the tasks that depend on the variables set by those tasks to
succeed in check mode.
Signed-off-by: Benoît Knecht <bknecht@protonmail.ch>
(cherry picked from commit 498acd7527)
We currently download the grafana dashboars from the ceph@master branch
for all ceph releases.
We should use the right ceph branch according to the ceph release.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
The radosgw-sync-overview and rbd-details grafana dashboars were missing
from the list.
Closes: #6758
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit f0ccf3ebf0)
Check early which Ceph release is going to be deployed and fail if it
doesn't correspond to the ceph-ansible version being used.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1978643
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit eec38784ec)
When using self-signed/untrusted CA certificates, alertmanager displays
an error in logs. With this commit this should make those messages
disappear.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1936299
Co-authored-by: Guillaume Abrioux <gabrioux@redhat.com>
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 9f77b929d1)
When the rgw_multisite_proto variable is set to https then we shoudn't use
the IP address in the zone endpoints list but the node FQDN to match the
TLS certificate CN.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1965504
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit ad05a08160)
This adds a task that zaps by osd id so we can support the scenario
where osds were deployed with `osd_auto_discovery` is true.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1876860
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 4144074a50)
This refactor merges the two playbooks so we only have to maintain 1
playbook.
(Symlink the old purge-container-cluster.yml playbook for backward
compatibility).
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 17cd83bf3a)
Those variables are useless given this is not possible to override them.
Let's replace them with the hardcoded name instead.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 6b50401d0c)
1303611 introduced tasks for disabling the pg_autoscaler on pools and
the balancer but thoses tasks are already executed on the first monitor
node so we don't need to add the run_once statement.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 738fa9428a)
When using python 2 and the task with a loop is skipped then it generates
an error.
Unexpected templating type error occurred on
({{ (pool_list.stdout | from_json)['pools'] }}): expected string or buffer
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit cf6e33346e)
The PG autoscaler can disrupt the PG checks so the idea here is to
disable it and re-enable it back after the restart is done.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 13036115e2)
Populating the ceph_mgr_modules list in the mgr_modules doesn't make sense
since that file is only executed if the list isn't empty or we're using the
dashboard.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit cd06e7c046)
We already have config override variables for existing block (like
ganesha_ceph_export_overrides, ganesha_log_overrides, etc...) or a
global one (ganesha_conf_overrides) but redefining the NFS_CORE_PARAM
block in that variable will erase all previous values (currently only
Bind_Addr).
ganesha_core_param_overrides: |
Enable_UDP = false;
NFS_Port = 2050;
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1941775
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 9817d29543)
This commit adds the support for zapping an osd by osd_id in the
ceph_volume module.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 70f1d6e2cd)
This commit reindents the playbook.
Also improve readability by adding an extra line between plays.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 60aa70a128)
If one a the monitor is out of the quorum then nothing prevents the upgrade
playbook to run.
We only check if we have at least three monitor nodes but we should also
check if those monitor nodes are correctly present in the quorum.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1952571
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 97148dd58c)
It's better to fail the playbook so the user is aware the straw2
migration has failed.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit c396122ad9)
After an upgrade, the presence of straw buckets will produce the
following warning (HEALTH_WARN):
```
crush map has legacy tunables (require firefly, min is hammer)
```
because straw bucket is a firefly feature it needs to be converted to
straw2.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1967964
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit eee576477c)
When deploying dashboard with ssl certificates generated by
ceph-ansible, we enforce the CN to 'ceph-dashboard' which can makes
application such alertmanager complain like following:
`err="Post https://mgr0:8443/api/prometheus_receiver: x509: certificate is valid for ceph-dashboard, not mgr0" context_err="context deadline exceeded"`
The idea here is to add alternative names matching all mgr/mon instances
in the certificate so this error won't appear in logs.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1978869
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 72a0336c71)
This commit ensure all ceph-ansible modules pass flake8 properly.
Signed-off-by: Wong Hoi Sing Edison <hswong3i@pantarei-design.com>
(cherry picked from commit beda1fe773)
The dashboard/monitoring stack can be deployed via the dashboard_enabled
variable. But there's nothing similar if we can to remove that part only
and keep the ceph cluster up and running.
The current purge playbooks remove everything.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1786691
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 8e4ef7d6da)
This introduces a new variable `dashboard_network` in order to support
deploying the dashboard on a different subnet.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1927574
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit f4f73b6197)
The ceph crash insatll checkpoint callback was missing in the main
playbooks.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 993d06c4d9)
Add any_errors_fatal: true in cephadm-adopt playbook.
We should stop the playbook execution when a task throws an error.
Otherwise it can lead to unexpected behavior.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1976179
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 3b804a61dd)
Instead of reusing the condition 'inventory_hostname in groups[osds]'
on each device facts tasks then we can move all the tasks into a
dedicated file and set the condition on the import_tasks statement.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit d704b05e52)
We currently don't check if the logical volume used in lvm_volumes list
for either bluestore data/db/wal or filestore data/journal exist.
We're only doing this on raw devices for batch scenario.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 55bca07cb6)
When using dedicated devices for db/journal/wal objecstore with
ceph-volume lvm batch then we should also validate that those devices
exist and don't use a gpt partition table in addition of the devices
and lvm_volume.data variables.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 808e7106de)
Instead of using findmnt command to find the device associated to the
root mount point then we can use the ansible_mounts fact.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 7e50380f7f)
Instead of doing two parted calls we can check first if the device exist
and then test the partition table.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 14d458b3b4)
2888c08 introduced a regression as the check_devices tasks file was
only included based on the devices variable.
But that file also validate some devices from the lvm_volumes variable.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1906022
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit ac0342b72e)