In a collocated scenario, where you might put a rgw, a mds and a mon on
the same node you don't want the handler blindly restart all the daemons
on the node. Indeed some of them might not be configured yet.
Implementing a more precise socket detection, for each daemon type.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1488813
Signed-off-by: Sébastien Han <seb@redhat.com>
This commits allows us to run
switch-from-non-containerized-to-containerized-ceph-daemons.yml multiple
times.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1489353
Signed-off-by: Sébastien Han <seb@redhat.com>
If devices is passed through an extra var this register won't work so
let's only register the var is devices is not defined.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1489099
Signed-off-by: Sébastien Han <seb@redhat.com>
Prior to this patch this activation sequence for autodetection was
always skipped because we were asking to activate on device without
partitions, which doesn't make sense.
We also fix the way we lookup for a device, since the data partition is
always numbered 1, we take the min element of the dict.
Closes: https://github.com/ceph/ceph-ansible/issues/1782
Signed-off-by: Sébastien Han <seb@redhat.com>
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Prior command was avoiding the lockbox mountpoint and the playbook was
failing with:
rmtree failed: [Errno 30] Read-only file system:
'/var/lib/ceph/osd-lockbox/4e9d8052-87c2-4fde-a56c-b8c108a3eefc/key-management-mode'
Signed-off-by: Sébastien Han <seb@redhat.com>
we need to force the value of `docker` variable which is initially set
to `false` since it's a migration from non-containerized to
containerized cluster.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Add new boolean parameter for client config create_key_file_only
with a default of false. When create_key_file_only is true, the
client tasks to connect to the external ceph cluster to verify
the key `ceph auth import` the key are skipped.
Fixes: #1848
CI slaves are slow so by setting a higher value we can avoid the following error:
Timeout (12s) waiting for privilege escalation prompt:
Now we wait for 32 sec...
More info here: https://github.com/ansible/ansible/issues/14426
Signed-off-by: Sébastien Han <seb@redhat.com>
We must mask the image so we are sure that even if the system reboots
then the OSDs won't start.
Also remove Ceph udev rules if found on the system prior to deploy
containers. If we don't do this we are exposed to conflicts between udev
rules and sytemd unit files.
Also add the CI will now test the migration from a non-containerized cluster to a
containerized cluster.
Signed-off-by: Sébastien Han <seb@redhat.com>
Monitor removal from the monmap is not immediate, so let's wait a little
bit and then fail if the monitor is still in the monmap.
We try twice in total with 10 sec intervals.
Signed-off-by: Sébastien Han <seb@redhat.com>