By changing the set ownership command from using the file module in combination with a with_items loop to a raw chown command, we can achieve a 98% performance increase here.
On a ceph cluster with a significant amount of directories and files in /var/lib/ceph, the file module has to run checks on ownership of all those directories and files to determine whether a change is needed.
In this case, we just want to explicitly set the ownership of all these directories and files to the ceph_uid
Added context note to all set proper ownership tasks
Signed-off-by: Kevin Jones <kevinjones@redhat.com>
(cherry picked from commit 47bf47c9d8)
CEPH_CONTAINER_IMAGE should be None if containerized_deployment
is False.
Resolves: #4498
Signed-off-by: Andrew Schoen <aschoen@redhat.com>
(cherry picked from commit 70a4368bc5)
This commit replaces a `command` task with `ceph_key` in order to create
mgr keyrings.
This allows us to use `mode` parameter to set the right mode on
generated keys.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1734513
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Since we change the way to run the OSD containers with the ID instead
of the device name, we lost the ability to use loop devices.
Loop devices are like nvme or cciss devices because the partitions are
referenced with an extra 'p' before the partition number.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1749097
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
In containerized deployment, the restart OSD handler couldn't be
triggered in most ansible execution.
This is due to the usage of run_once + a condition on the inventory
hostname and the last filter.
The run_once is triggered first so ansible will pick a node in the
osd group to execute the restart task. But if this node isn't the
last one in the osd group then the task is ignored. There's more
probability that the task will be ignored than executed.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 5b1c15653f)
The ceph-rbd-mirror role allows to copy the admin keyring via the
copy_admin_key variable but there's actually no task in that role
doing the job.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 1f505628dd)
The admin keyring isn't present by default on the rbd mirror nodes so
the rbd commands related to the mirroring confguration will fail.
Instead we can use the rbd mirror client keyring.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit a3d36df025)
Ganesha cannot be operated active/active, in those deployments
where it is managed by pacemaker the container name can be
different than the default.
This change uses "ceph_nfs_service_suffix" where previously
missing to ensure tasks will work with customized names.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1750005
Signed-off-by: Giulio Fidente <gfidente@redhat.com>
(cherry picked from commit d2a2bd7c42)
The rbd mirror configuration was only available for non containerized
deployment and was also imcomplete.
We now enable the mirroring on the pool and add the remote peer in both
scenarios.
The default mirroring mode is set to 'pool' but can be configured via
the ceph_rbd_mirror_mode variable.
This commit also fixes an issue on the rbd mirror command if the ceph
cluster name isn't using the default value (ceph) due to a missing
--cluster parameter to the command.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1665877
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 7e5e21741e)
5b29144 change the mgr node to a dedicated node instead of the first
monitor node.
But the change didn't update the switch-to-containers inventory which
cause this playbook to fail.
Also update the ubuntu inventory to have the same configuration.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
We don't have a reason to not apply firewall rules on the host when
using a containerized deployment.
The TripleO environments already manage the ceph firewall rules outside
ceph-ansible and set the configure_firewall variable to false.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1733251
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 771f25b1f8)
Like the OpenStack keyrings, we can use the profile rbd for the clients
keyring (both mon and osd).
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 49aa05b96c)
This reverts commit 2d955757ee.
The "osd blacklist" isn't an osd caps but should be used with mon caps.
Also the correct caps for this is: 'allow command "osd blacklist"'.
The current change is breaking the openstack and clients keyrings.
By using the profile rbd (which is already used) we already rely on the
ability to blacklist dead client.
Resolves: #4385
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 717af83475)
On containerized deployment, the OSD entrypoint runs some ceph-volume
commands (lvm/simple scan and/or activate) which perform badly without
the ulimit option.
This option was added for all previous ceph-volume commands but not on
the ceph-osd container startup.
Also updating hard limit value to 4096 to reflect default baremetal
value.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1744390
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 9a4ac46d19)
This can't be backported from master since there was too many
modifications meantime.
When mgr aren't all ready, sometimes the following error can show up:
```
stderr: 'Error ENOENT: all mgr daemons do not support module ''status'', pass --force to force enablement'
```
This commit adds a check so all mgr are available when we try to enable
modules.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
ceph-volume will complain if gpt headers are found on devices.
This commit checks whether a gpt header is present on devices passed in
`devices` variable and fail early.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1730541
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 487d701685)
In `stable-4.0`, the group name `iscsi-gws` will go away and some rgw
systemd service names will disappear as well:
(`ceph-rgw@<hostname>.service`, `ceph-radosgw@<hostname>.service`,
`ceph-radosgw@radosgw.<hostname>.service`,
`ceph-radosgw@radosgw.gateway.service`)
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
we must use the ids instead of device names in the tasks executed in
`post_tasks` for the osd rolling update otherwise it ends up with old
systemd units enabled.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1739209
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Otherwise it will fail when running rolling_update.yml playbook because
of `serial: 1` usage.
The task which copies the script is run against the current node being
played only whereas the task which runs the script is run against all
nodes in a loop, it ends up with the typical error:
```
2019-08-08 17:47:05,115 p=14905 u=ubuntu | failed: [magna023 -> magna030] (item=magna030) => {
"changed": true,
"cmd": [
"/usr/bin/env",
"bash",
"/tmp/systemd-device-to-id.sh"
],
"delta": "0:00:00.004339",
"end": "2019-08-08 17:46:59.059670",
"invocation": {
"module_args": {
"_raw_params": "/usr/bin/env bash /tmp/systemd-device-to-id.sh",
"_uses_shell": false,
"argv": null,
"chdir": null,
"creates": null,
"executable": null,
"removes": null,
"stdin": null,
"warn": true
}
},
"item": "magna030",
"msg": "non-zero return code",
"rc": 127,
"start": "2019-08-08 17:46:59.055331",
"stderr": "bash: /tmp/systemd-device-to-id.sh: No such file or directory",
"stderr_lines": [
"bash: /tmp/systemd-device-to-id.sh: No such file or directory"
],
"stdout": "",
"stdout_lines": []
}
```
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1739209
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
let's deploy mgr on a dedicated node.
This makes update job failing on stable-4.0 branch since there's a
mismatch between the two inventories.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
This commits adds the `osd blacklist` cap on all OSP clients keyrings.
Fixes: #2296
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 2d955757ee)
Since bedc0ab we now manage ceph-osd systemd unit scripts based on ID
instead of device name but it was not present in the shrink-osd
playbook (ceph-disk version).
To keep backward compatibility on deployment that didn't do yet the
transition on OSD id then we should stop unit scripts for both device
and ID.
This commit adds the ulimit nofile container option to get better
performance on ceph-disk commands.
It also fixes an issue when the OSD id matches multiple OSD ids with
the same first digit.
$ ceph-disk list | grep osd.1
/dev/sdb1 ceph data, prepared, cluster ceph, osd.1, block /dev/sdb2
/dev/sdg1 ceph data, prepared, cluster ceph, osd.12, block /dev/sdg2
Finally removing the shrinked OSD directory.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
Allow to configure the rgw beast frontend in addition to civetweb
(default value).
Add rgw_thread_pool_size variable with 512 as default value and keep
backward compatibility with num_threads option when using civetweb.
Update radosgw_civetweb_num_threads to reflect rgw_thread_pool_size
change.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1733406
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit d17b1b48b6)
When creating OpenStack pools, we only check if the return code from
the pool list command isn't 0 (ie: if it doesn't exist). In that case,
the return code will be 2. That's why the next condition is rc != 0 for
the pool creation.
But in containerized deployment, the return code could be different if
there's a failure on the container engine command (like container not
running). In that case, the return code could but either 1 (docker) or
125 (podman) so we should fail at this point and not in the next tasks.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1732157
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit d549fffdd2)
The ooo-collocation scenario was still using an old container image and
doesn't match the requirement on latest stable-3.2 code. We need to use
at least the container image v3.2.5.
Also updating the OSD tests to reflect the changes introduced by the
commit bedc0ab because we don't have the OSD systemd unit script using
device name anymore.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
Some NBSP are still present in the yaml files.
Adding a test in travis CI.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 07c6695d16)
When using containerized deployment we have to create the systemd
service unit based on a template.
The current implementation with ceph-disk is using the device name
as paramater to the systemd service and for the container name too.
$ systemctl start ceph-osd@sdb
$ docker ps --filter 'name=ceph-osd-*'
CONTAINER ID IMAGE NAMES
065530d0a27f ceph/daemon:latest-luminous ceph-osd-strg0-sdb
This is the only scenario (compared to non containerized or
ceph-volume based deployment) that isn't using the OSD id.
$ systemctl start ceph-osd@0
$ docker ps --filter 'name=ceph-osd-*'
CONTAINER ID IMAGE NAMES
d34552ec157e ceph/daemon:latest-luminous ceph-osd-0
Also if the device mapping doesn't persist to system reboot (ie sdb
might be remapped to sde) then the OSD service won't come back after
the reboot.
This patch allows to use the OSD id with the ceph-osd systemd service
but requires to activate the OSD manually with ceph-disk first in
order to affect the ID to that OSD.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1670734
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
Both ntp and chrony daemon use variable for the service name because it
could be different depending on the GNU/Linux distribution.
This has been update in 9d88d3199 for chrony but only for the start part
not for the handler.
The commit fixes this for both ntp and chrony.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 0ae0193144)
nfs-ganesha v2.5 and 2.6 have hit EOL. Install nfs-ganesha v2.7
stable that is currently being maintained.
Signed-off-by: Ramana Raja <rraja@redhat.com>
(cherry picked from commit dfff89ce67)
The message prints the whole content of the registered variable in the
playbook, this is not needed and makes the message pretty unclear and
unreadable.
```
"msg": "{'_ansible_parsed': True, 'changed': False, '_ansible_no_log': False, u'err': u'Error: Could not stat device /dev/sdf - No such file or directory.\\n', 'item': u'/dev/sdf', '_ansible_item_result': True, u'failed': False, '_ansible_item_label': u'/dev/sdf', u'msg': u\"Error while getting device information with parted script: '/sbin/parted -s -m /dev/sdf -- unit 'MiB' print'\", u'rc': 1, u'invocation': {u'module_args': {u'part_start': u'0%', u'part_end': u'100%', u'name': None, u'align': u'optimal', u'number': None, u'label': u'msdos', u'state': u'info', u'part_type': u'primary', u'flags': None, u'device': u'/dev/sdf', u'unit': u'MiB'}}, 'failed_when_result': False, '_ansible_ignore_errors': None, u'out': u''} is not a block special file!"
```
Fixes: https://bugzilla.redhat.com/show_bug.cgi?id=1719023
(cherry picked from commit e6dc3ebd8c)
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
When shrinking an OSD, its corresponding 'prepare container' should be
removed otherwise it prevent from redeploying a new osd because of this
leftover.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Removing the gpt header on devices will ease ceph-disk to ceph-volume
migration when using shrink-osd + add-osd playbooks.
ceph-disk requires GPT header where ceph-volume will complain if GPT
header is present.
That won't break ceph-disk (re)deployment since we check and add the GPT
header if needed when deploying ceph-disk ODs.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1613735
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
If the SOCKET variable isn't defined in the script then the test
command won't fail because the return code is 0
$ test -S
$ echo $?
0
There multiple issues in that script:
- The default SOCKET value isn't defined.
- Update the wget parameters because the command is doing a loop.
We now use the same option than curl.
- The check_rest function doesn't test the radosgw at all due to
a wrong test command (test against a string) and always returns 0.
This needs to use the DOCKER_EXEC variable in order to execute the
command.
$ test 'wget http://192.168.100.11:8080'
$ echo $?
0
Resolves: #3926
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit c90f605b51)
The rgw restart script set the RGW_IP variable depending on ansible
variables:
- radosgw_address
- radosgw_address_block
- radosgw_interface
Those variables have default values defined in ceph-defaults role:
radosgw_interface: interface
radosgw_address: 0.0.0.0
radosgw_address_block: subnet
But in the rgw restart script we always use the radosgw_address value
instead of the radosgw_interface when defined because we aren't testing
the right default value.
As a consequence, the RGW_IP variable will be set to 0.0.0.0 even if
the ip address associated to the radosgw_interface variable is set
correctly. This causes the check_rest function to fail.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
Alphabetized ceph_repository_uca keys due to errors validating when
using UCA/queens repository on Ubuntu 16.04
An exception occurred during task execution. To see the full
traceback, use -vvv. The error was:
SchemaError: -> ceph_stable_repo_uca schema item is not
alphabetically ordered
Closes: #4154
Signed-off-by: Gabriel Ramirez <gabrielramirez1109@gmail.com>
(cherry picked from commit 82262c6e8c)
789cef7 introduces a regression in the ganesha configuration file
generation. The new config_template module version broke it.
But the ganesha.conf file isn't an ini file and doesn't really
need to use the config_template module. Instead we can use the
classic template module.
Resolves: #4045
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 616c484698)
This tries to first unmount any cephfs/nfs-ganesha mount point on client
nodes, then unmap any mapped rbd devices and finally it tries to remove
ceph kernel modules.
If it fails it means some resources are still busy and should be cleaned
manually before continuing to purge the cluster.
This is done early in the playbook so the cluster stays untouched until
everything is ready for that operation, otherwise if you try to redeploy
a cluster it could end up by getting confused by leftover from previous
deployment.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1337915
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 20e4852888)
ceph-facts should be run before we play ceph-validate since it has
reference to facts that are set in ceph-facts role.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
This was removed because of broken repositories which made the CI
failing. That doesn't make sense anymore so adding back it
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
Same behaviour than ceph-volume (b987534). The ceph-disk command runs
faster when using ulimit nofile with container cli.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
There's two big issues with the current OSD restart script.
1/ We try to test if the ceph osd daemon socket exists but we use a
wildcard for the socket name : /var/run/ceph/*.asok.
This fails because we usually have multiple ceph osd sockets (or
other ceph daemon collocated) present in /var/run/ceph directory.
Currently the test fails with:
bash: line xxx: [: too many arguments
But it doesn't stop the script execution.
Instead we can specify the full ceph osd socket name because we
already know the OSD id.
2/ The container filter pattern is wrong and could matches multiple
containers resulting the script to fail.
We use the filter with two different patterns. One is with the device
name (sda, sdb, ..) and the other one is with the OSD id (ceph-osd-0,
ceph-osd-15, ..).
In both case we could match more than needed.
$ docker container ls
CONTAINER ID IMAGE NAMES
958121a7cc7d ceph-daemon:latest ceph-osd-strg0-sda
589a982d43b5 ceph-daemon:latest ceph-osd-strg0-sdb
46c7240d71f3 ceph-daemon:latest ceph-osd-strg0-sdaa
877985ec3aca ceph-daemon:latest ceph-osd-strg0-sdab
$ docker container ls -q -f "name=sda"
958121a7cc7d
46c7240d71f3
877985ec3aca
$ docker container ls
CONTAINER ID IMAGE NAMES
2db399b3ee85 ceph-daemon:latest ceph-osd-5
099dc13f08f1 ceph-daemon:latest ceph-osd-13
5d0c2fe8f121 ceph-daemon:latest ceph-osd-17
d6c7b89db1d1 ceph-daemon:latest ceph-osd-1
$ docker container ls -q -f "name=ceph-osd-1"
099dc13f08f1
5d0c2fe8f121
d6c7b89db1d1
Adding an extra '$' character at the end of the pattern solves the
problem.
Finally removing the get_container_osd_id function because it's not
used in the script at all.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 45d46541cb)
The ceph-volume lvm list command takes ages to complete when having
a lot of LV devices on containerized deployment.
For instance, with 25 OSDs on a node it takes 3 mins 44s to list the
OSD.
Adding the max open files limit to the container engine cli when
executing the ceph-volume command seems to improve a lot thee
execution time ~30s.
This was impacting the OSDs creation with ceph-volume (both filestore
and bluestore) when using multiple LV devices.
Closes: https://bugzilla.redhat.com/show_bug.cgi?id=1702285
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit b987534881)
Otherwise content in /run/udev is mislabeled and prevent some services
like NetworkManager from starting.
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 80875adba7)
Since timesyncd is not available on RHEL-based OSs, change the default
to chronyd for RHEL-based OSs. Also, chronyd is chrony on Ubuntu, so
set the Ansible fact accordingly.
Fixes: https://github.com/ceph/ceph-ansible/issues/3628
Signed-off-by: Rishabh Dave <ridave@redhat.com>
(cherry picked from commit 9d88d3199f)
Since Atomic doesn't allow any installations and NTPd is not present
on Atomic image we are using, abort when ntp_daemon_type is set to ntpd.
https://github.com/ceph/ceph-ansible/issues/3572
Signed-off-by: Rishabh Dave <ridave@redhat.com>
(cherry picked from commit bdff3e48fd)
The ceph-agent role was used only for RHCS 2 (jewel) so it's not
usefull anymore.
The current code will fail on CentOS distribution because the rhscon
package is only avaible on Red Hat with the RHCS 2 repository and
this ceph release is supported on stable-3.0 branch.
Resolves: #4020
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 7503098ca0)
Because we're using vagrant, a ssh config file will be created for
each nodes with options like user, host, port, identity, etc...
But via tox we're override ANSIBLE_SSH_ARGS to use this file. This
remove the default value set in ansible.cfg.
Also adding PreferredAuthentications=publickey because CentOS/RHEL
servers are configured with GSSAPIAuthenticationis enabled for ssh
server forcing the client to make a PTR DNS query.
Signed-off-by: Dimitri Savineau <dsavinea@redhat.com>
(cherry picked from commit 34f9d51178)
if we don't assign the rbd application tag on this pool,
the cluster will get `HEALTH_WARN` state like following:
```
HEALTH_WARN application not enabled on 1 pool(s)
POOL_APP_NOT_ENABLED application not enabled on 1 pool(s)
application not enabled on pool 'rbd'
```
Signed-off-by: Guillaume Abrioux <gabrioux@redhat.com>
(cherry picked from commit 4cf17a6fdd)